Electric Transformers

Electric transformers are static electrical machines that transform electric power from one circuit to the other without changing the frequency. An electrical transformer can increase or decrease the voltage with...
�
Please fill out the following form to submit a Request for Quote to any of the following companies listed on
This article takes an in-depth look at power transformers.
Read further and learn more about topics such as:
Power transformers are crucial electrical devices engineered to transfer electrical energy between circuits without changing the frequency. They work on the basis of electromagnetic induction and are pivotal in delivering power from generators to primary distribution systems. Power transformers are tasked with adjusting voltage levels in distribution networks by either stepping up or stepping down the voltage. These static devices have no moving or rotating parts, operating effectively within an alternating current (AC) system.
These transformers are categorized based on their voltage range, usually spanning from 33 kV to 400 kV, and they often hold ratings above 200 MVA. Common voltage ratings for power transformers are 400 kV, 200 kV, 110 kV, 66 kV, and 33 kV. In contrast, other transformer types, such as distribution transformers, operate within voltage ranges of 230 V to 11 kV, along with instrument transformers.
Power transformers play an essential role in minimizing substantial energy losses attributed to Joule’s effect, especially when transmitting large volumes of electrical power across extensive distances. They accomplish this by converting electrical energy to high voltage for effective transmission before stepping it down to safer, low voltages. These transformers find extensive use in power plants, industrial establishments, and electric utility firms.
Power transformers are essential devices in electrical power systems, enabling the safe and efficient transmission and distribution of electrical energy. Their operation is fundamentally based on Faraday’s law of electromagnetic induction, a core principle in electrical engineering and transformer design. Understanding this law is critical for comprehending how transformers work and why they are vital components in power grids, substations, industrial applications, and renewable energy systems.
Faraday’s law states that an electromotive force (emf) is induced across a closed-loop conductor whenever it is exposed to a changing magnetic field. In practical terms, this means that when an alternating voltage is applied to the primary winding of a transformer, it creates a time-varying magnetic flux within the iron core. This fluctuating magnetic flux efficiently links to the secondary winding due to the high magnetic permeability of the core material.
When alternating current (AC) passes through the primary coil (winding), an oscillating magnetic field is established. The ferromagnetic core serves as a low-reluctance path, maximizing magnetic coupling and minimizing core losses. As the magnetic flux varies, it induces an emf in the secondary winding, effectively transferring energy from the input side to the output side without direct electrical connection. This critical principle of electromagnetic induction guarantees galvanic isolation and flexible voltage regulation, which are key factors in modern electrical distribution and safety.
High-efficiency power transformers leverage advanced core materials, such as silicon steel or amorphous metals, and are engineered to minimize eddy current losses and hysteresis losses. These features are crucial for optimizing performance, reducing heat generation, and ensuring reliability in utility substations, industrial plants, and renewable energy installations.
Transformers are designed to step voltages up or down based on specific application needs, such as increasing voltage for long-distance transmission or decreasing it for local distribution and end-user safety. The total voltage in a given winding is the product of the voltage per turn of the coil and the number of coil turns. Since the voltage per turn is equal for both primary and secondary windings, the voltage induced in the secondary (output) winding is directly related to the input voltage of the primary winding. This relationship forms the basis of the transformer equation:
Vs = (Vp/Np) x Ns
Where V is the voltage, N denote the number of turns in the winding, and the subscripts p and s refer to primary and secondary windings, respectively. The turns ratio (Ns/Np) determines whether the transformer functions as a step-up transformer (increasing voltage) or a step-down transformer (decreasing voltage). This is critical in power transmission networks, where high voltages are used for efficiency, while lower voltages are required for residential, commercial, and industrial users.
When the secondary winding has fewer turns than the primary winding, the transformer outputs a lower voltage (step-down configuration), commonly used in household power supplies and electronic devices. Conversely, if the secondary winding has more turns, it outputs a higher voltage (step-up transformer), which is vital for long-distance transmission to reduce line losses. These operational modes ensure reliable, flexible voltage adaptation for a wide variety of applications, from utility substations and renewable energy plants to electronic devices and heavy industrial machinery.
To maintain energy conservation, the relationship between the alternating currents and voltages in the primary and secondary windings follows the law of conservation of power:
Vp Ip = Vs Is
Here, I represents the current in each winding. While voltage changes, the total delivered power (minus system losses) remains nearly constant, ensuring efficient energy transfer. Understanding this fundamental relationship helps engineers optimize transformer sizing, select appropriate core materials, and ensure compliance with industry standards such as IEEE, IEC, and ANSI.
Modern power transformers come in a wide range of designs, including distribution transformers, isolation transformers, autotransformers, and instrument transformers like current and potential transformers. Each type is tailored for specific applications in utility grids, industrial automation, power generation, and renewable energy systems. Key considerations when choosing a transformer include voltage rating, power capacity (kVA or MVA), efficiency, cooling methods (oil-immersed or dry-type), and compliance with safety standards and energy efficiency regulations.
Operators, engineers, and procurement specialists often evaluate transformer performance based on criteria such as load losses, no-load losses, impedance, temperature rise, tap changer options, and maintenance requirements. These factors significantly influence lifecycle costs and reliability. Selecting a reputable manufacturer or supplier can provide additional benefits such as custom engineering support, advanced testing, and after-sales services.
By understanding the operating principles and technical considerations outlined above, users can make informed decisions when sourcing, installing, or maintaining power transformers for mission-critical applications across the electrical power industry.
Power transformers are vital equipment in electrical power distribution and transmission systems, designed to step up or step down voltage levels efficiently and safely. Understanding their fundamental components is key to maximizing transformer performance, reliability, and lifespan. While all transformers share common building blocks, such as the magnetic core and electrical windings, power transformers incorporate specialized subsystems and advanced features to meet the rigorous demands of high-voltage and high-capacity grid applications. This chapter explores the main transformer components in detail, enhancing your knowledge of design, maintenance, and troubleshooting of power transformers and related electrical equipment.
The transformer core is a central structural and magnetic element that supports the windings and provides a path of low magnetic reluctance for magnetic flux. Constructed by stacking and laminating thin, high-grade electrical steel sheets, the core minimizes core losses—specifically eddy currents and hysteresis losses—which are critical factors in transformer energy efficiency and performance. To further reduce losses, these laminated sheets typically measure less than one millimeter thick and have a carbon content below 0.1%. Alloying with silicon increases electrical resistance, suppressing eddy currents and enhancing overall system efficiency. The vertical segments of the core, termed limbs, accommodate the windings, while the horizontal sections connecting the limbs are known as yokes. Transformer core design and construction directly influence magnetic flux distribution, transformer noise, and load handling capacity, all vital factors in power engineering.
Transformer windings, the primary and secondary coils, are typically made of copper or aluminum. High-purity copper is favored for its superior electrical conductivity, thermal stability, and mechanical flexibility, ensuring minimal resistive losses and improved transformer efficiency. The precise number of turns in each winding determines the voltage transformation ratio, impacting operational safety, voltage regulation, and power quality.
A transformer contains at least two windings: the primary winding (receiving input voltage) and the secondary winding (delivering output voltage). Depending on transformer application and system specifications, either winding may be designated as the high voltage (HV) or low voltage (LV) side. Accurate identification and proper arrangement of windings are essential for safe transformer operation, coordinated grid integration, and fault protection:
Optimizing the placement and configuration of HV and LV windings is critical for reducing leakage reactance, controlling fault currents, and ensuring energy-efficient, low-loss transformer performance in modern electrical networks.
For three-phase transformers, windings may be connected in star (Y) or delta (Δ) configurations to balance system requirements, enhance phase voltage control, and support transformer paralleling.
Insulation is vital in transformers, safeguarding windings from short circuits, electrical arcing, and breakdowns caused by elevated voltages. High-dielectric strength materials such as electrical-grade paper, pressboard, and composite fiberglass are used for winding insulation, while transformer oil provides additional insulation and cooling for high-power transformers. In dry-type transformers, solid insulation systems are standard, though they may require frequent inspection and replacement due to thermal and electrical aging.
Transformer oil, typically composed of hydrocarbons like aromatics, paraffins, naphthenes, and olefins, is widely used for insulating, cooling, and servicing large oil-immersed transformers. Besides offering excellent dielectric properties, mineral oil inhibits oxidation of internal components, provides fault detection by gas evolution, and extends service life. For higher environmental safety and fire resistance, synthetic esters and biodegradable fluids may be used as alternative insulating liquids. Maintaining insulation quality—such as controlling dissolved moisture and preventing contamination—is essential for transformer longevity, energy efficiency, and prevention of catastrophic failures.
Tap changers are mechanical or on-load devices used in power transformers for voltage regulation, allowing utility operators and industrial facilities to maintain consistent output voltage despite fluctuations in supply voltage or load changes. By varying the number of active turns in one winding, the tap changer adjusts the turns ratio and, thus, the output voltage, which is crucial during grid voltage instability or for balancing load across multiple circuits. Tap changers are usually installed on the high-voltage side to minimize current and mechanical stress during operation.
Two primary tap changer types include: On-load tap changers (OLTC), enabling voltage adjustment without de-energizing the transformer, critical for uninterrupted power supply and grid stability, and off-load tap changers (NLTC), which require transformer shutdown for safe operation. The selection depends on grid requirements, application criticality, and maintenance schedules.
Bushings act as high-voltage insulators that allow safe passage of electrical conductors through the transformer tank, preventing electrical flashover and dielectric breakdown. Typically fabricated from porcelain or epoxy resin, these components withstand severe electrical, thermal, and mechanical stresses. Proper bushing selection and periodic maintenance are imperative to ensuring transformer protection, reducing downtime, and complying with industry standards such as IEEE or IEC.
The transformer tank, also known as the main tank, is a robust, oil-tight enclosure that houses and shields the transformer core, windings, and auxiliary components from environmental hazards like moisture, dust, and temperature variations. It doubles as a reservoir for insulating and cooling fluids and is fabricated from rolled steel plates or aluminum sheets for mechanical strength, ease of fabrication, and corrosion resistance.
Large power transformers often incorporate additional mechanical features such as stiffeners, inspection windows, and lifting lugs. In oil-immersed transformers, the main tank interfaces with vital accessories like radiators, breathers, conservators, and Buchholz relays, which collectively ensure operational safety and efficient heat removal.
The conservator is a cylindrical auxiliary tank located above the main tank and bushings, designed as an expansion chamber for transformer oil. It accommodates oil expansion resulting from temperature variations, maintaining a constant oil level and reducing the risk of tank rupture due to overpressure. A flexible bladder or diaphragm separates the oil from atmospheric air, minimizing oxidation and moisture ingress to prolong transformer service life. The conservator is critical in ensuring thermal compensation, hydraulic balancing, and maintaining consistent transformer dielectric integrity in power systems.
The breather, usually containing silica gel, conditions atmospheric air entering the conservator to remove humidity and particulates, thus preventing moisture from deteriorating transformer oil insulation properties. An effective breather prolongs oil life, improves dielectric performance, and prevents corrosion of transformer internals. Monitoring the silica gel color offers a simple maintenance indicator of absorption capacity and the need for replacement. Maintaining dry, clean air inside the tank is essential for maximizing transformer insulation resistance and mitigating risk of failures caused by internal arcing or dielectric breakdown.
Moisture and dissolved water in transformer oil can severely compromise insulation strength and activate internal faults, leading to transformer outages or catastrophic failure. Ensuring proper breather functioning is vital for asset reliability and operational safety.
The cooling system is indispensable for dissipating the heat generated during transformer operation, a direct consequence of core losses (hysteresis and eddy currents), copper losses (I2R), and stray losses. Inadequate cooling can result in excessive temperature rise, leading to accelerated aging of insulation, reduced transformer efficiency, or complete equipment failure.
Various cooling methods are used based on transformer type, voltage rating, and application requirements:
For oil-immersed power transformers, advanced cooling mechanisms include:
Accurate temperature monitoring and control via temperature sensors, thermostats, and relays promote safe operation, energy efficiency, and preventive maintenance, especially in critical power generation and industrial distribution systems.
The explosion vent is a crucial transformer safety device, consisting of a metallic pipe and diaphragm, installed above the conservator tank. It provides a dedicated outlet for the rapid release of gases and oil during severe internal faults, protecting both personnel and equipment from transformer explosions or catastrophic tank ruptures. When internal pressure rises to unsafe levels, the vented diaphragm bursts at a pre-set threshold, discharging gases and preventing damage. Maintaining explosion vents in proper working condition is critical for compliance with electrical safety regulations and power transformer standards.
The Buchholz relay is a specialized protective relay mounted in the pipe between the conservator and main oil tank. It detects the accumulation of fault gases, such as those produced by arcing or overheating, providing early warning of incipient transformer faults. When sufficient gas is collected, the relay activates the alarm and trip circuits, prompting shutdown or immediate attention. The Buchholz relay is widely regarded as a key asset for transformer condition monitoring, predictive maintenance, and grid security, especially in medium to large oil-filled power transformers.
For additional information on transformer components or to discuss custom transformer design and selection for your specific application, industry professionals may explore the latest standards, specifications, and best practices from leading organizations such as IEEE, IEC, and ANSI. Choosing the appropriate transformer components and maintenance strategies is pivotal for ensuring grid reliability, reducing downtime, and optimizing total cost of ownership.
Power transformers can be classified according to their core and winding construction, turns ratio, number of phases, and core material.
1. Core and Winding Design and Configuration
Berry-type transformers have a core designed like the spokes of a wheel. They utilize distributed magnetic circuits and contain multiple independent magnetic circuits, typically more than two.
In core-type transformers, the primary and secondary windings encircle the core. The core is made by joining two L-shaped steel strips, which are then stacked to create the core layers. To minimize reluctance at the joints, the strips are arranged to avoid continuous joints. The flux is carried by the limbs and yoke of the core.
In shell-type transformers, the core encircles both the primary and secondary windings. The core is constructed from E-shaped and I-shaped steel strips, which are stacked to form layers. In this design, the central limb of the core carries the entire magnetic flux, while the side limbs each carry half of the flux.
2. Turns Ratio (Ns/Np)
Isolation transformers have a turns ratio equal to 1, which means the number of turns in the primary and secondary windings is equal. They are used to isolate the load from the power source while supplying alternating currents. They protect the electrical device, operation, and persons from electrical noise, shock, and damage. They are commonly used in computers, measurement devices, industrial machinery, laboratory and medical equipment, and other sensitive equipment.
Step-down transformers have a turns ratio of less than 1, which means that the primary winding has more turns. These transformers convert the high voltage and low current input from the primary winding to a low voltage and high current output on the secondary winding.
In electricity distribution, step-up transformers are located at power generating stations, while step-down transformers are installed at substations. This application is further illustrated in the image below:
Step-up transformers have a turns ratio greater than 1, which means that the secondary winding has more turns. These transformers convert the low voltage and high current input from the primary winding to a high voltage and low current output on the secondary winding.
3. Phases
Autotransformers consist of a single winding tapped at certain points across its length to supply a fraction of the primary voltage. The primary and secondary windings are linked to each other, which are wounded on a single core. Autotransformers have a more compact size and are cheaper than the conventional double winding transformer, which can deliver the same VA rating. However, they do not have electrical isolation between the primary and secondary windings. They are widely used in induction motors, railways, audio systems, and lighting systems.
Single-phase transformers consist of a single pair of windings arranged around a core and produce a single alternating voltage, represented by a single sine wave. They feature four terminals, with each winding having two terminals. These transformers do not include star (wye) or delta connections.
Single-phase transformers have a straightforward construction and are commonly used in residential and light commercial power supplies. They are particularly prevalent in rural areas where electrical demand is lower, making them a cost-effective choice for such applications.
Three-phase transformers are composed of three pairs of primary and secondary windings. They can be constructed by connecting three single-phase transformers to form a transformer bank or by assembling three pairs of windings into a single laminated core. Three-phase transformers generate three-phase alternating current flowing in separate conductors. Three sine waves represent this, and the waves are separated by 120 degrees from one another. The amplitude is reached more frequently which makes three-phase transformers supply power at an almost constant rate.
The windings of both the primary and secondary sides of three-phase transformers can be connected in either delta or star configurations. These connections can be the same or different on the primary and secondary sides. As a result, several configurations of three-phase transformers are possible:
Three-phase transformers are preferred for heavy-duty applications due to their efficient utilization of winding connections. They are widely used in large motors, electric power distribution networks, and other significant loads. Moreover, three-phase transformers are more economical than using three single-phase transformers to achieve the same VA rating.
4. Core Material
Air core transformers lack a physical core. Instead, their primary and secondary windings are wrapped in a solid insulating material. These transformers are commonly used for transmitting radio-frequency currents.
Ferrite core transformers utilize a core made of ferrite, a ceramic material composed of iron oxides, zinc, nickel, and manganese. Common types of ferrites used in transformers include manganese-zinc ferrite and nickel-zinc ferrite.
Ferrites are known for their high magnetic permeability, which enhances the flow of magnetic flux through the material. They also offer high electrical resistivity and low eddy current losses across a broad frequency range, making them well-suited for high-frequency applications. As a result, ferrite core transformers are commonly employed in wideband transformers and various electronics applications.
Iron core transformers feature an electromagnetic core constructed from laminated iron sheets. This type is the most commonly used within this category. Iron cores provide high flux linkage due to their excellent magnetic properties, making them effective for a wide range of applications.
Toroidal core transformers have cores shaped like toruses or donuts, constructed from iron or ferrite. The primary and secondary windings are wound around these ring-shaped cores. The toroidal design reduces magnetic flux leakage and enhances both inductance and Q factors, leading to high efficiency. These transformers are often used in telecommunications, power distribution, and industrial control systems.
Power transformers experience four main types of losses that influence their efficiency:
Copper losses, also known as resistive or I²R losses, occur due to the electrical resistance in the windings as current flows through them. The resistance of the winding material, which affects these losses, depends on factors such as the material’s length, cross-sectional area, nature, and temperature. The amount of current flowing through the windings also impacts copper losses. These losses are quantified using the formula I²R.
Hysteresis losses arise from the friction experienced by the ferromagnetic molecules in the core during the magnetization and demagnetization processes. As the magnetizing force alternates between forward and reverse directions, internal friction generates heat within the transformer.
Eddy currents are generated in the core's cross-section due to fluctuating magnetic fields. To minimize these losses, transformer cores are constructed from thin, laminated metal sheets. Each lamina is insulated with a special coating, which reduces the path available for eddy currents and limits their flow.
Flux losses occur when some magnetic flux lines from the primary winding bypass the secondary winding and flow through the air instead. This can happen due to magnetic saturation of the core, where the core is unable to accommodate additional flux lines. Additionally, the difference in reluctance between the air and the core can contribute to these losses.
Electric transformers are static electrical machines that transform electric power from one circuit to the other without changing the frequency. An electrical transformer can increase or decrease the voltage with...
An isolation transformer, just like typical transformers, is a non-moving device that transmits electrical energy from one circuit to another without requiring any physical contact. It works on the idea of magnetic...
An electrical transformer is a passive machine that transfers electrical energy from one circuit to another using a magnetic flux to induce an electromotive force. Transformers are used to increase (step-up) or decrease (step-down) voltages without changing the frequency of the electric current...
A toroidal transformer is a type of electrical transformer constructed with a torus or donut-shaped core. Its primary and secondary windings are wound across the entire surface of the torus core separated by an insulating material...
Electronically operated equipment depends on power transformers to convert electrical currents into voltage. Current transformers store and transport energy through power lines and grids...
Power supplies are electrical circuits and devices that are designed to convert mains power or electricity from any electric source to specific values of voltage and current for the target device...
An AC power supply is a type of power supply used to supply alternating current (AC) power to a load. The power input may be in an AC or DC form. The power supplied from wall outlets (mains supply) and...
An AC power cord is a detachable way of providing an alternating current of electric energy from a mains power supply to an electrical appliance or equipment. Serving industries like...
A DC DC power supply (also known as DC DC Converter) is a kind of DC power supply that uses DC voltage as input instead of AC/DC power supplies that rely on AC mains supply voltage as an input...
A DC power supply is a type of power supply that gives direct current (DC) voltage to power a device. Because DC power supply is commonly used on an engineer‘s or technician‘s bench for a ton of power tests...
An electric coil, or electromagnetic coil, is an electrical conductor that contains a series of conductive wires wrapped around a ferromagnetic core that is cylindrical, toroidal, or disk-like. Electric coils are one of the simplest forms of electronic components and provide...
Electrical plugs, commonly known as power plugs, are devices responsible for supplying and drawing current from a receptacle to the circuitry of an electrical appliance...
By definition a power supply is a device that is designed to supply electric power to an electrical load. An electrical load refers to an electrical device that uses up electric power. Such a device can be anything from...
Inductors are passive two terminal components of an electric or electronic circuit that are capable of storing energy in magnetic form. They oppose sudden changes in current and they are also called coils or chokes...
A NEMA connector is a method for connecting electronic devices to power outlets. They can carry alternating current (AC) or direct current (DC). AC current is the typical current found in homes, offices, stores, or businesses...
A power cord is an electrical component used for connecting appliances to an electrical utility or power supply. It is made from an insulated electrical cable with one or both ends molded with connectors...
A programmable power supply is a method for controlling output voltage using an analog or digitally controlled signal using a keypad or rotary switch from the front panel of the power supply...
A solenoid coil is a common electrical component that uses a wire that is tightly wrapped around a core, usually made of metal, to generate an electromagnetic field. When an electrical current is passed through the coil, the electromagnetic field that is created provides energy for linear motion...
A voice coil is a winding of a wire, usually copper, aluminum, or copper-clad aluminum that is wrapped around a former (often called a bobbin) and then attached to the apex of a speaker cone...
Thomas Edison developed the power distribution system in 1882. He wrapped a copper rod in jute, a soft shiny fiber from plants, as an insulator. The jute wrapped copper rod was placed in a pipe with a bituminous compound...